Specifications
| Brand | Siemens |
|---|---|
| Model Number | MH-501 |
| Official Product Name | Pressure Transmitter MH-501 |
| Applicable System | Industrial process control, HVAC, water treatment |
| Product Type | Pressure Transmitter |
| Equivalent Standard | CE, EMC Directive 2014/30/EU |
| Product Status | In Stock |
| Output Signal | 4-20 mA (2-wire) |
| Accuracy | ±0.5% of span |
| Supply Voltage | 10-30 VDC |
| Process Connection | G1/2 male |
| Housing Material | Stainless steel (1.4301) |
| Measuring Cell | Ceramic (Al2O3) |
| Operating Temperature | -20°C to +85°C (-4°F to +185°F) |
| Process Temperature | -20°C to +100°C (-4°F to +212°F) |
| Protection Class | IP65 |
| Weight | Approx. 0.3 kg (0.66 lbs) |
| Electrical Connection | DIN 43650 connector (ISO 4400) |
| Measuring Range | 0 to 16 bar (0 to 232 psi) |
Product Description
Home > Products > Siemens > Pressure Transmitters Need Siemens MH-501? Pressure Transmitter for Industrial process control, HVAC, water treatment. Supplied with full traceability and documentation. Request... Price & Availability It is part of Siemens' extensive range of process instrumentation, engineered for harsh environments and demanding processes. The transmitter converts pressure into a standard 4-20 mA analog output signal, making it compatible with most PLCs, DCS, and control systems. Its robust construction ensures long-term stability and minimal maintenance, ideal for continuous operation in industrial settings. This model features a measuring range of 0 to 16 bar (0 to 232 psi) with a 4-20 mA output, powered by a 10-30 VDC supply. It offers high accuracy of ±0.5% of span, ensuring precise readings for critical processes. The MH-501 is designed with a stainless steel housing and a ceramic measuring cell, providing excellent resistance to corrosion and mechanical stress. It is suitable for use with gases, liquids, and steam, making it versatile across various industries. The MH-501 is easy to install and configure, with a standard G1/2 process connection and an optional display for local reading. It is certified to CE standards and complies with EMC directives, ensuring safe and reliable operation. Whether used in water treatment, HVAC, or general process control, the Siemens MH-501 delivers dependable performance. As a genuine OEM part, it meets Siemens' stringent quality requirements, offering a cost-effective solution for pressure monitoring needs. The Siemens MH-501 is a compact pressure transmitter designed for industrial automation applications, providing reliable and accurate pressure measurement. Basic Product Information Output signal 4-20 mA (2-wire) Accuracy ±0.5% of span Supply voltage 10-30 VDC Ceramic measuring cell for high corrosion resistance Stainless steel housing for durability Process connection G1/2 male CE certified and EMC compliant Measuring range 0-16 bar (0-232 psi) Technical Specifications Version & Model Difference The Siemens MH-501 is part of the MH series of pressure transmitters. Variations include different measuring ranges (e.g., 0-1 bar, 0-100 bar) and output options (e.g., 0-10 V). The MH-501 specifically denotes the 0-16 bar range with 4-20 mA output. Other models in the series may have different process connections (e.g., 1/4 NPT) or optional displays. Always verify the exact model code for your application. Application Scenarios What output signal does the MH-501 provide? The MH-501 provides a standard 4-20 mA analog output signal (2-wire), which is widely accepted by PLCs, DCS, and other control systems. What is the supply voltage requirement for the MH-501? The transmitter operates with a supply voltage of 10-30 VDC. It is typically powered by a 24 VDC supply commonly used in industrial automation. Is the MH-501 suitable for use with corrosive media? Yes, the MH-501 features a ceramic measuring cell and stainless steel housing, providing excellent resistance to corrosion. However, for highly corrosive media, verify compatibility with the wetted materials. What is the measuring range of the Siemens MH-501? The MH-501 has a measuring range of 0 to 16 bar (0 to 232 psi). It is designed for industrial pressure measurement applications within this range. Siemens 6ES7214-1BH50-0XB0 PLC CPU (Type-1) Siemens 6ES7231-4HF50-0XB0 Analog Input Module Siemens 6ES7231-5PD50-0XB0 Analog RTD Module Siemens 6ES7231-5QF50-0XB0 Analog TC Module (S7-1200) Siemens 6ES7233-4HF50-0XB0 Analog IO Module (SM 1234) Siemens 6ES7216-2BD23-0XB0 PLC CPU (Type-2) Siemens 6ES7223-1BH22-0XA0 PLC IO Module (Type-1) Siemens 6ES7223-5PH50-0XB0 PLC IO Module (Type-2)