Home Products About Us Blog Contact Get a Quote →
Siemens · PLC Module

5SY6332-8

Siemens Component 5SY6332-8 / 5SY6 D 32A/3P

Siemens Siemens

Siemens Component 5SY6332-8 / 5SY6 D 32A/3P

Home > Products > Siemens > Circuit Breakers > 5SY6332-8 Need Siemens 5SY6332-8 / 5SY6 D 32A/3P? Component for Electrical distribution systems, swi…

$15.00
In Stock

Auto-extracted from partner page

Specifications

BrandSiemens
Model Number5SY6332-8 / 5SY6 D 32A/3P
Official Product NameCircuit Breaker (EFH)
Applicable SystemElectrical distribution systems, switchgear, control panels
Product TypeComponent (Miniature Circuit Breaker)
Equivalent Standard5SY6332-8, 5SY6 D 32A/3P
Product StatusActive
Standard Frame PolesEN 60898, IEC 60947-2
Rated Current (A)32 A
Tripping CurveD
Rated Voltage (V)440 V
Breaking Capacity (kA)6kA
Mounting TypeDIN rail
Terminal Capacity1-25 mm2
Degree of ProtectionIP20 (with connected conductors)
Operating Temperature-25 to +55 degC
StandardsIEC 60898-1, EN 60898-1
Poles/Positions3
Breaking Capacity6 kA (EN 60898); Icu 15 kA (IEC 60947-2)
Dimensions90 x 54 x 76 mm, install depth 70 mm, 3 modular units
Weight~0.42 kg (420 g)
Frame Style6kA

Product Description

Home > Products > Siemens > Circuit Breakers > 5SY6332-8 Need Siemens 5SY6332-8 / 5SY6 D 32A/3P? Component for Electrical distribution systems, switchgear, control panels. Supplied with full traceability and... Price & Availability 15.00 USD (参考价 / est. market price) It is intended for use within Electrical distribution systems, switchgear, control panels, where dependable operation and a precise fit are essential to keeping the plant running. Listed as Active, it is offered as a maintained and verified spare that supports the continued operation of the installed base. Key technical specifications include: The Frame Style is 6kA. Its Standard Frame Poles is rated at EN 60898, IEC 60947-2. For reference, the Rated Current (A) is 32 A. The Tripping Curve is D. Its Rated Voltage (V) is rated at 440 V. For reference, the Breaking Capacity (kA) is 6kA. The Mounting Type is DIN rail. Its Degree of Protection is rated at IP20 (with connected conductors). For reference, the Operating Temperature is -25 to +55 degC. The Standards is IEC 60898-1, EN 60898-1. Its Poles/Positions is rated at 3. For reference, the Breaking Capacity is 6 kA (EN 60898); Icu 15 kA (IEC 60947-2). Notable features of this unit: 3-pole miniature circuit breaker with D tripping curve for high inrush currents. Rated current of 32A and breaking capacity of 6kA per IEC 60898-1. Compact design for DIN rail mounting, suitable for industrial panels. Typical applications include Industrial motor protection in control panels, Commercial building electrical distribution boards, Transformer protection in power distribution, New installations in switchgear assemblies. It is compatible with or cross-references Siemens 5SY6 series accessories (e.g., auxiliary contacts, shunt trips), Siemens SENTRON busbar systems, Siemens 3VA molded case circuit breakers (for higher ratings), Siemens 5SM6 residual current devices (RCDs). Equivalent / cross-reference designation: 5SY6332-8, 5SY6 D 32A/3P. Within industrial automation and process-control environments, components of this type are relied upon to keep critical equipment operating safely and efficiently. They are typically specified where uptime, repeatability and a predictable maintenance cycle matter more than upfront cost. Siemens parts are widely used across power generation, manufacturing, oil and gas, water and process industries, where engineering teams standardise on proven series to simplify spares planning. When selecting a replacement, confirm the exact model designation and verify that the mechanical and electrical interface matches the unit currently installed. Cross-checking the order code, mounting style and connection type against the existing device helps avoid compatibility issues and unplanned downtime during a maintenance window. Where several variants exist, the suffix often defines voltage, range or firmware, so it should be matched precisely rather than approximated. This item is offered from our active stock of current and discontinued industrial parts. Each listing is verified against the manufacturer designation before shipment so you receive the correct part for your application. Availability and lead time vary by item; our team can confirm the fastest option for your required quantity and provide a formal quotation on request. Common questions: Regarding "What is the breaking capacity of the Siemens 5SY6332-8": The breaking capacity is 6kA according to IEC 60898-1, suitable for most industrial and commercial applications. Regarding "What is the tripping curve of the 5SY6 D 32A/3P": It has a D tripping curve, which allows for high inrush currents, making it ideal for motor and transformer circuits. Please contact us to confirm current pricing, availability and delivery for your required quantity; volume and project pricing are available on request. The Siemens 5SY6332-8 / 5SY6 D 32A/3P is a miniature circuit breaker. Basic Product Information Rated current of 32A and breaking capacity of 6kA per IEC 60898-1 Compact design for DIN rail mounting, suitable for industrial panels High reliability and long electrical life, compliant with international standards Clear visual indication of switch position for easy maintenance 3-pole miniature circuit breaker with D tripping curve for high inrush currents Technical Specifications Version & Model Difference The Siemens 5SY6 series includes various breaking capacities (6kA, 10kA, 15kA) and different tripping curves (B, C, D). The 5SY6332-8 is specifically a 6kA, 3-pole, 32A, D-curve version. It is equivalent to the 5SY6 D 32A/3P designation. There are no significant regional differences for this model; it is a standard product globally. Application Scenarios Industrial motor protection in control panels Commercial building electrical distribution boards Transformer protection in power distribution Replacement for existing 5SY6 series breakers in maintenance New installations in switchgear assemblies What is the tripping curve of the 5SY6 D 32A/3P? It has a D tripping curve, which allows for high inrush currents, making it ideal for motor and transformer circuits. Is the 5SY6332-8 a 3-pole breaker? Yes, it is a 3-pole miniature circuit breaker with a rated current of 32A. Can the 5SY6332-8 be used in residential applications? While it can be used in residential settings, it is primarily designed for industrial and commercial use due to its D curve and higher breaking capacity. What is the breaking capacity of the Siemens 5SY6332-8? The breaking capacity is 6kA according to IEC 60898-1, suitable for most industrial and commercial applications. Siemens 6ES7214-1BH50-0XB0 PLC CPU (Type-1) Siemens 6ES7231-4HF50-0XB0 Analog Input Module Siemens 6ES7231-5PD50-0XB0 Analog RTD Module Siemens 6ES7231-5QF50-0XB0 Analog TC Module (S7-1200) Siemens 6ES7233-4HF50-0XB0 Analog IO Module (SM 1234) Siemens 6ES7216-2BD23-0XB0 PLC CPU (Type-2) Siemens 6ES7223-1BH22-0XA0 PLC IO Module (Type-1) Siemens 6ES7223-5PH50-0XB0 PLC IO Module (Type-2)

READY TO SHIP · 48H

Need 5SY6332-8?
Get a Quote in Minutes.

12-month warranty · No MOQ · Worldwide shipping with tracking

Request a Quote

Get the latest price, stock status and bulk order discount for 5SY6332-8. Our team replies within 30 minutes (working hours).

Get Instant Quote