5SY6232-8
Siemens Component 5SY6232-8 / 5SY6 D 32A/2P

Siemens
Siemens Component 5SY6232-8 / 5SY6 D 32A/2P
Home > Products > Circuit Breakers > Siemens > 5SY6232-8 Need Siemens 5SY6232-8 / 5SY6 D 32A/2P? Component for Low voltage electrical distribution …
Specifications
| Brand | Siemens |
|---|---|
| Model Number | 5SY6232-8 / 5SY6 D 32A/2P |
| Official Product Name | Circuit Breaker (EFH) |
| Applicable System | Low voltage electrical distribution systems |
| Product Type | Component (Miniature Circuit Breaker) |
| Equivalent Standard | 5SY6232-8, 5SY6 D 32A/2P |
| Product Status | Active |
| Number of Poles | 2 |
| Rated Current (A) | 32 A |
| Tripping Curve | D |
| Rated Voltage (V) | 400 V AC (230/400 V) |
| Breaking Capacity (kA) | 6 |
| Mounting Type | DIN Rail |
| Terminal Capacity | 1-25 mm2 |
| Degree of Protection | IP20 |
| Operating Temperature | -25 to +55 degC |
| Standards | EN 60898, IEC 60947-2 |
| Breaking Capacity | 6 kA (EN 60898) |
| Dimensions | 90 x 36 x 76 mm, install depth 70 mm, 2 modular units |
| Weight | ~0.30 kg (2-pole family) |
| Frame Style | 6kA |
Product Description
Home > Products > Circuit Breakers > Siemens > 5SY6232-8 Need Siemens 5SY6232-8 / 5SY6 D 32A/2P? Component for Low voltage electrical distribution systems. Supplied with full traceability and documentation.... Price & Availability 13.00 USD (参考价 / est. market price) It is intended for use within Low voltage electrical distribution systems, where dependable operation and a precise fit are essential to keeping the plant running. Listed as Active, it is offered as a maintained and verified spare that supports the continued operation of the installed base. Key technical specifications include: The Frame Style is 6kA. Its Number of Poles is rated at 2. For reference, the Rated Current (A) is 32 A. The Tripping Curve is D. Its Rated Voltage (V) is rated at 400 V AC (230/400 V). For reference, the Breaking Capacity (kA) is 6. The Mounting Type is DIN Rail. Its Degree of Protection is rated at IP20. For reference, the Operating Temperature is -25 to +55 degC. The Standards is EN 60898, IEC 60947-2. Its Breaking Capacity is rated at 6 kA (EN 60898). For reference, the Dimensions is 90 x 36 x 76 mm, install depth 70 mm, 2 modular units. Notable features of this unit: Rated current 32A for reliable overcurrent protection. 2-pole configuration for single-phase or two-phase circuits. D tripping curve for high inrush current applications. 6kA breaking capacity for industrial environments. Compact modular design for DIN rail mounting. Typical applications include Industrial motor protection, Transformer protection, Commercial electrical panels, HVAC systems, Pump control systems, Machine tool equipment. It is compatible with or cross-references Siemens 5SY6 series MCBs (other ratings), Siemens 5SM6 series RCCBs, Siemens 5TT series contactors. Equivalent / cross-reference designation: 5SY6232-8, 5SY6 D 32A/2P. The Siemens 5SY6 series includes various versions with different current ratings, pole configurations, and tripping curves. The 5SY6232-8 specifically denotes a 32A, 2-pole, D-curve breaker. Other versions may have different current ratings (e.g., 6A, 10A, 16A, 20A, 25A, 40A) or curves (B, C, D). The 5SY6 series is the standard miniature circuit breaker range from Siemens, suitable for residential, commercial, and industrial applications. Within industrial automation and process-control environments, components of this type are relied upon to keep critical equipment operating safely and efficiently. They are typically specified where uptime, repeatability and a predictable maintenance cycle matter more than upfront cost. Siemens parts are widely used across power generation, manufacturing, oil and gas, water and process industries, where engineering teams standardise on proven series to simplify spares planning. When selecting a replacement, confirm the exact model designation and verify that the mechanical and electrical interface matches the unit currently installed. Cross-checking the order code, mounting style and connection type against the existing device helps avoid compatibility issues and unplanned downtime during a maintenance window. Where several variants exist, the suffix often defines voltage, range or firmware, so it should be matched precisely rather than approximated. This item is offered from our active stock of current and discontinued industrial parts. Each listing is verified against the manufacturer designation before shipment so you receive the correct part for your application. Availability and lead time vary by item; our team can confirm the fastest option for your required quantity and provide a formal quotation on request. Common questions: Regarding "What is the breaking capacity of the Siemens 5SY6232-8": The breaking capacity is 6kA, suitable for most industrial and commercial installations. Regarding "What is the tripping curve of this circuit breaker": It has a D tripping curve, which allows for higher inrush currents without nuisance tripping, ideal for motor and transformer loads. Please contact us to confirm current pricing, availability and delivery for your required quantity; volume and project pricing are available on request. The Siemens 5SY6232-8 / 5SY6 D 32A/2P is a miniature circuit breaker. Basic Product Information 2-pole configuration for single-phase or two-phase circuits D tripping curve for high inrush current applications 6kA breaking capacity for industrial environments Compact modular design for DIN rail mounting Complies with international standards (IEC 60898, EN 60898) Rated current 32A for reliable overcurrent protection Technical Specifications Version & Model Difference The Siemens 5SY6 series includes various versions with different current ratings, pole configurations, and tripping curves. The 5SY6232-8 specifically denotes a 32A, 2-pole, D-curve breaker. Other versions may have different current ratings (e.g., 6A, 10A, 16A, 20A, 25A, 40A) or curves (B, C, D). The 5SY6 series is the standard miniature circuit breaker range from Siemens, suitable for residential, commercial, and industrial applications. Application Scenarios Industrial motor protection Transformer protection Commercial electrical panels Pump control systems Machine tool equipment What is the tripping curve of this circuit breaker? It has a D tripping curve, which allows for higher inrush currents without nuisance tripping, ideal for motor and transformer loads. Is this circuit breaker suitable for single-phase applications? Yes, with 2 poles, it can be used for single-phase (live and neutral) or two-phase (two live wires) applications. Can I use this breaker for residential applications? While it is primarily designed for industrial use, it can be used in residential settings if the electrical characteristics match the requirements. What is the breaking capacity of the Siemens 5SY6232-8? The breaking capacity is 6kA, suitable for most industrial and commercial installations. Siemens 6ES7214-1BH50-0XB0 PLC CPU (Type-1) Siemens 6ES7231-4HF50-0XB0 Analog Input Module Siemens 6ES7231-5PD50-0XB0 Analog RTD Module Siemens 6ES7231-5QF50-0XB0 Analog TC Module (S7-1200) Siemens 6ES7233-4HF50-0XB0 Analog IO Module (SM 1234) Siemens 6ES7216-2BD23-0XB0 PLC CPU (Type-2) Siemens 6ES7223-1BH22-0XA0 PLC IO Module (Type-1) Siemens 6ES7223-5PH50-0XB0 PLC IO Module (Type-2)