LC1D150M7C
Schneider Component LC1D150M7C

Schneider Electric
Schneider Component LC1D150M7C
Home > Products > Contactors > Schneider > LC1D150M7C Need Schneider LC1D150M7C? Component for Motor control, power switching, industrial automatio…
Contact us for current availability and best price of LC1D150M7C.
Specifications
| Brand | Schneider |
|---|---|
| Model Number | LC1D150M7C |
| Official Product Name | Contactor |
| Applicable System | Motor control, power switching, industrial automation |
| Product Type | Component (contactor) |
| Equivalent Standard | TeSys D LC1D150M7C, LC1D150M7C equivalent |
| Product Status | Active |
| Rated operational voltage | 690VAC |
| Coil voltage | 220VAC 50/60Hz |
| Number of poles | 3 |
| Utilization category | AC-3, AC-4 |
| Mechanical durability | 10 million operations |
| Electrical durability | 1 million operations (AC-3) |
| Mounting type | Screw or DIN rail |
| Terminal type | Screw terminals |
| Weight | 1.2 kg |
| Dimensions (W x H x D) | 85 x 120 x 110 mm |
| Standards | IEC 60947, UL 508, CSA C22.2 |
| Rated operational current (AC-3) | 150A |
Product Description
Home > Products > Contactors > Schneider > LC1D150M7C Need Schneider LC1D150M7C? Component for Motor control, power switching, industrial automation. Supplied with full traceability and documentation. Request a... Price & Availability Contact us for pricing / 询价 It is intended for use within Motor control, power switching, industrial automation, where dependable operation and a precise fit are essential to keeping the plant running. Listed as Active, it is offered as a maintained and verified spare that supports the continued operation of the installed base. Key technical specifications include: The Coil voltage is 220VAC 50/60Hz. Its Number of poles is rated at 3. For reference, the Utilization category is AC-3, AC-4. The Mechanical durability is 10 million operations. Its Electrical durability is rated at 1 million operations (AC-3). For reference, the Mounting type is Screw or DIN rail. The Weight is 1.2 kg. Its Dimensions (W x H x D) is rated at 85 x 120 x 110 mm. For reference, the Standards is IEC 60947, UL 508, CSA C22.2. Notable features of this unit: Coil voltage: 220VAC 50/60Hz. 3-pole configuration for three-phase applications. Compact design with easy mounting and wiring. High electrical endurance and mechanical durability. Complies with IEC, UL, CSA standards. Typical applications include Motor starting and stopping in conveyors, pumps, fans, Power switching in industrial machinery, HVAC systems and refrigeration units, Automation panels and control cabinets. It is compatible with or cross-references Schneider LADN22C auxiliary contact block, Schneider LAD7B106C surge suppressor, Schneider LAD4BBU interface module, Schneider LRD365 thermal overload relay (up to 150A). Equivalent / cross-reference designation: TeSys D LC1D150M7C, LC1D150M7C equivalent. The LC1D150M7C is part of the TeSys D series. There are variants with different coil voltages (e.g., LC1D150M7C for 220VAC, LC1D150M7C for 24VAC/DC). The 'M7C' suffix indicates the coil voltage and control circuit. This model is the standard version with 220VAC coil. Other versions may have different coil voltages or include auxiliary contacts. Always verify the coil voltage and auxiliary configuration for your application. Within industrial automation and process-control environments, components of this type are relied upon to keep critical equipment operating safely and efficiently. They are typically specified where uptime, repeatability and a predictable maintenance cycle matter more than upfront cost. Schneider parts are widely used across power generation, manufacturing, oil and gas, water and process industries, where engineering teams standardise on proven series to simplify spares planning. When selecting a replacement, confirm the exact model designation and verify that the mechanical and electrical interface matches the unit currently installed. Cross-checking the order code, mounting style and connection type against the existing device helps avoid compatibility issues and unplanned downtime during a maintenance window. Where several variants exist, the suffix often defines voltage, range or firmware, so it should be matched precisely rather than approximated. Availability for this item is confirmed against current stock and supplier lead times at the point of enquiry. Each listing is verified against the manufacturer designation before shipment so you receive the correct part for your application. Contact our team with your required quantity to obtain pricing, lead time and a formal quotation. Common questions: Regarding "What is the coil voltage of the Schneider LC1D150M7C contactor": The coil voltage is 220VAC 50/60Hz. Ensure your control circuit matches this voltage. Regarding "Can the LC1D150M7C be used for motor starting": Yes, it is suitable for motor starting applications up to 150A in AC-3 category, commonly used for three-phase motors. Please contact us with your model and required quantity so we can confirm availability, lead time and pricing for your application. The Schneider LC1D150M7C is a contactor. Basic Product Information Coil voltage: 220VAC 50/60Hz 3-pole configuration for three-phase applications Compact design with easy mounting and wiring High electrical endurance and mechanical durability Complies with IEC, UL, CSA standards Optional auxiliary contact blocks and accessories available Rated operational current: 150A (AC-3) Technical Specifications Version & Model Difference The LC1D150M7C is part of the TeSys D series. There are variants with different coil voltages (e.g., LC1D150M7C for 220VAC, LC1D150M7C for 24VAC/DC). The 'M7C' suffix indicates the coil voltage and control circuit. This model is the standard version with 220VAC coil. Other versions may have different coil voltages or include auxiliary contacts. Always verify the coil voltage and auxiliary configuration for your application. Application Scenarios Motor starting and stopping in conveyors, pumps, fans Power switching in industrial machinery HVAC systems and refrigeration units Automation panels and control cabinets Replacement for existing contactors in maintenance and retrofit projects Can the LC1D150M7C be used for motor starting? Yes, it is suitable for motor starting applications up to 150A in AC-3 category, commonly used for three-phase motors. What is the difference between LC1D150M7C and LC1D150M7C? The LC1D150M7C is the standard version with 220VAC coil. Other versions may have different coil voltages (e.g., 24VAC, 110VAC) or include auxiliary contacts. Check the full model number for specifications. Is the LC1D150M7C a direct replacement for other contactors? It is designed to replace equivalent TeSys D contactors with similar ratings. Always verify electrical ratings and physical dimensions before replacement. What is the coil voltage of the Schneider LC1D150M7C contactor? The coil voltage is 220VAC 50/60Hz. Ensure your control circuit matches this voltage. Schneider P343318H3M0368k Generator Differential Prot Schneider P342318L3M0368J Generator Backup Prot Schneider P39191R00A Rotary Ground Injection Unit Schneider P991_22888911118889C Test Block Schneider P643318E3M0A08K Transforme Differential Prot Schneider P142318M0468J Transformer Backup Protection Schneider P991-8889888922889C Test Block Schneider P44331BN-6MO-D18M Line Distance Protection
Need LC1D150M7C?
Get a Quote in Minutes.
12-month warranty · No MOQ · Worldwide shipping with tracking
Request a Quote
Get the latest price, stock status and bulk order discount for LC1D150M7C. Our team replies within 30 minutes (working hours).
