Schneider Electric
Schneider Contactor LC1-D09E7
Home > Products > Schneider > Contactors Need Schneider LC1-D09E7? Contactor for Industrial automation, motor control, lighting control. Supplied with…
Contact us for current availability and best price of LC1-D09E7.
Specifications
| Brand | Schneider Electric |
|---|---|
| Model Number | LC1-D09E7 |
| Official Product Name | TeSys D Contactor - 3P(3NO) - AC-3 - 9A - 48V AC 50/60Hz coil |
| Applicable System | Industrial automation, motor control, lighting control |
| Product Type | Contactor |
| Equivalent Standard | IEC 60947, UL, CSA |
| Product Status | In Stock |
| Number of Poles | 3P (3NO) |
| Rated Operational Current (Ie) | 9A (AC-3) at 400V |
| Rated Control Circuit Voltage (Uc) | 48V AC 50/60Hz |
| Coil Consumption (AC) | 7.5 VA (inrush), 7.5 VA (hold) |
| Rated Operational Voltage (Ue) | Up to 690V AC |
| Rated Thermal Current (Ith) | 25A at 40°C |
| Mechanical Durability | 15 million cycles |
| Electrical Durability (AC-3) | 1.4 million cycles |
| Terminal Type | Screw clamp terminals |
| Mounting Support | 35mm DIN rail or screw fixing |
| Standards | IEC 60947-4-1, UL 508, CSA C22.2 |
| Product Range | TeSys D |
Product Description
Home > Products > Schneider > Contactors Need Schneider LC1-D09E7? Contactor for Industrial automation, motor control, lighting control. Supplied with full traceability and documentation. Request a... Price & Availability Contact us for pricing / 询价 It features a rated operational current of 9A (AC-3) and a coil voltage of 48V AC 50/60Hz, making it suitable for a wide range of switching tasks. The contactor is built with high-quality materials and undergoes rigorous testing to ensure reliable performance and long electrical life. This contactor is part of the TeSys D range, known for its modularity and ease of installation. It offers a compact design that saves panel space, while its screw clamp terminals ensure secure and simple wiring. The LC1-D09E7 is compatible with a full range of accessories including auxiliary contact blocks, mechanical interlocks, and surge suppressors, allowing for flexible configuration to meet specific application requirements. With a mechanical durability of up to 15 million operating cycles and an electrical durability of up to 1.4 million cycles (AC-3), the LC1-D09E7 ensures long-term reliability. It complies with international standards such as IEC 60947, UL, and CSA, making it suitable for global use. The contactor is ideal for applications like motor starting, lighting control, and power switching in various industries. The Schneider LC1-D09E7 is a compact 3-pole contactor from the TeSys D series, designed for controlling motors and electrical loads in industrial automation applications. Basic Product Information Rated operational current: 9A (AC-3) at 400V Coil voltage: 48V AC 50/60Hz High mechanical durability: up to 15 million cycles Screw clamp terminals for secure wiring Compatible with TeSys D accessories (auxiliary contacts, interlocks, surge suppressors) Compact 3-pole design for space-saving installation Technical Specifications Version & Model Difference The LC1-D09E7 is part of the TeSys D series, which includes various coil voltage versions (e.g., E7 = 48V AC, B7 = 24V AC, F7 = 110V AC). The 'D09' indicates the frame size and current rating (9A). Compared to older TeSys contactors, the D series offers improved compactness and modularity. The LC1-D09E7 is a standard version without built-in surge suppression; for applications with high inrush currents, consider adding a separate surge suppressor (e.g., LA4-DA2). Application Scenarios What is the rated current of the LC1-D09E7? The rated operational current is 9A in AC-3 utilization category (for motor switching) at 400V. In AC-1 category, it can handle up to 25A (thermal current). Can I use this contactor for DC loads? The LC1-D09E7 is primarily designed for AC loads. For DC switching, it is recommended to use DC-rated contactors or consult Schneider Electric for derating guidelines. What accessories are compatible with the LC1-D09E7? It accepts TeSys D auxiliary contact blocks (e.g., LADN11), mechanical interlocks (LA9-D09), surge suppressors (LA4-DA2), and thermal overload relays (LR2-D13). These accessories snap onto the contactor for easy installation. What is the coil voltage of the LC1-D09E7? The coil voltage is 48V AC 50/60Hz. Ensure your control circuit provides this voltage to energize the contactor. Schneider LC1D150M7C Contactor (150A, 220VAC, 3-Pole) Schneider P343318H3M0368k Generator Differential Prot Schneider P342318L3M0368J Generator Backup Prot Schneider P39191R00A Rotary Ground Injection Unit Schneider P991_22888911118889C Test Block Schneider P643318E3M0A08K Transforme Differential Prot Schneider P142318M0468J Transformer Backup Protection Schneider P991-8889888922889C Test Block
Need LC1-D09E7?
Get a Quote in Minutes.
12-month warranty · No MOQ · Worldwide shipping with tracking
Request a Quote
Get the latest price, stock status and bulk order discount for LC1-D09E7. Our team replies within 30 minutes (working hours).