NCB10-30GM40-N0-V1
Pepperl+Fuchs Inductive proximity sensor NCB10-30GM40-N0-V1

Other Brands
Pepperl+Fuchs Inductive proximity sensor NCB10-30GM40-N0-V1
['Home', 'Sensors', 'Inductive Sensors', 'Pepperl+Fuchs NCB10-30GM40-N0-V1'] Need Pepperl+Fuchs NCB10-30GM40-N0-V1? Ind…
Specifications
| Brand | Pepperl+Fuchs |
|---|---|
| Model Number | NCB10-30GM40-N0-V1 |
| Official Product Name | NAMUR Inductive Proximity Sensor NCB10-30GM40-N0-V1 |
| Applicable System | Intrinsically safe / hazardous-area detection |
| Product Type | Inductive proximity sensor (NAMUR) |
| Equivalent Standard | Contact supplier for exact specifications |
| Product Status | Active |
| Output type | NAMUR, normally closed (N/C) |
| Safety integrity | SIL2 |
| Connection | M12 connector |
| Target | Ferrous and non-ferrous metal |
| Housing | Contact supplier for exact specifications |
| Supply / barrier | Contact supplier for exact specifications |
| Sensing range | 10 mm (flush) |
Product Description
['Home', 'Sensors', 'Inductive Sensors', 'Pepperl+Fuchs NCB10-30GM40-N0-V1'] Need Pepperl+Fuchs NCB10-30GM40-N0-V1? Inductive proximity sensor for Intrinsically safe / hazardous-area detection. Supplied with full traceability and... Price & Availability It is intended for use within Intrinsically safe / hazardous-area detection, where dependable operation and a precise fit are essential to keeping the plant running. Listed as Active, it is offered as a maintained and verified spare that supports the continued operation of the installed base. Key technical specifications include: The Sensing range is 10 mm (flush). Its Safety integrity is rated at SIL2. For reference, the Connection is M12 connector. The Target is Ferrous and non-ferrous metal. Its Housing is rated at Contact supplier for exact specifications. For reference, the Supply / barrier is Contact supplier for exact specifications. Notable features of this unit: 10 mm flush-mount sensing range for metal targets. Normally-closed (N/C) switching function. M12 connector for quick installation. Typical applications include Position and presence detection in Ex areas, Hazardous-area machine safety loops, Metal object counting and end-stop sensing. It is compatible with or cross-references Intrinsically safe barriers (MTL / P+F K-series), M12 sensor cables and connectors. Equivalent / cross-reference designation: Contact supplier for exact specifications. Within industrial automation and process-control environments, components of this type are relied upon to keep critical equipment operating safely and efficiently. They are typically specified where uptime, repeatability and a predictable maintenance cycle matter more than upfront cost. Pepperl+Fuchs parts are widely used across power generation, manufacturing, oil and gas, water and process industries, where engineering teams standardise on proven series to simplify spares planning. When selecting a replacement, confirm the exact model designation and verify that the mechanical and electrical interface matches the unit currently installed. Cross-checking the order code, mounting style and connection type against the existing device helps avoid compatibility issues and unplanned downtime during a maintenance window. Where several variants exist, the suffix often defines voltage, range or firmware, so it should be matched precisely rather than approximated. This item is offered from our active stock of current and discontinued industrial parts. Each listing is verified against the manufacturer designation before shipment so you receive the correct part for your application. Availability and lead time vary by item; our team can confirm the fastest option for your required quantity and provide a formal quotation on request. Common questions: Regarding "What is the sensing range of the NCB10-30GM40-N0-V1": It has a 10 mm flush-mount sensing range for metal targets. Regarding "What connection does it use": It uses an M12 connector for straightforward installation. Please contact us to confirm current pricing, availability and delivery for your required quantity; volume and project pricing are available on request. The Pepperl+Fuchs NCB10-30GM40-N0-V1 is an industrial component. Basic Product Information NAMUR output for intrinsic safety with a barrier Normally-closed (N/C) switching function M12 connector for quick installation SIL2 functional safety certified 10 mm flush-mount sensing range for metal targets Technical Specifications Version & Model Difference The NCB10-30GM40-N0-V1 is the 10 mm flush N/C NAMUR variant with M12 connector; non-flush, N/O and cable versions exist in the NCB10 family. Select by range and connection. Contact supplier for exact specifications. Application Scenarios Position and presence detection in Ex areas Hazardous-area machine safety loops Metal object counting and end-stop sensing What connection does it use? It uses an M12 connector for straightforward installation. Is it safety certified? Yes. The sensor is SIL2 certified for functional safety applications. What output logic does it have? It provides a NAMUR normally-closed (N/C) output for use with an intrinsic safety barrier. What is the sensing range of the NCB10-30GM40-N0-V1? It has a 10 mm flush-mount sensing range for metal targets. Pepperl+Fuchs KFD2-SR2-EX2.W Isolation Amplifier Safety Barrier Pepperl+Fuchs KFD2-CD-EX1.32 Isolated Safety Barrier Pepperl+Fuchs NCN4-12GM35-N0-10M NAMUR Inductive Sensor Pepperl+Fuchs KCD2-RR2-Ex1 Resistance Repeater Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master Pepperl+Fuchs KFD2-WAC2-1.D Strain Gauge Converter Pepperl+Fuchs KFD2-DWB-Ex1.D Rotation Speed Monitor