Specifications
| Brand | Rosemount (Emerson) |
|---|---|
| Model Number | 3051SFA1G040CCHPS1T100T32JA1A3RLQ4M5 |
| Official Product Name | 3051SFA Annubar Flow Meter |
| Applicable System | Industrial flow measurement |
| Product Type | Annubar Flow Meter |
| Equivalent Standard | Contact supplier for cross-reference and alternative models |
| Product Status | Active |
| Lifecycle note | Available |
| Flow Accuracy | Up to +/-0.80% of flow (Ultra for Flow: +/-0.04% of reading) |
| Stability | Up to +/-0.15% URL over 15 years |
| Turndown | Up to 200:1 (14:1 flow turndown) |
| Line Size | 2 to 96 in (50 to 2440 mm) |
| Communication | 4-20 mA HART, WirelessHART, FOUNDATION Fieldbus |
| Wetted Materials | 316 SST, Alloy C-276 |
| Differential Pressure Range | Up to 1000 inH2O (2.48 bar) |
| Pressure Range | Up to 3626 psia / 3626 psig (250 bar) |
| Safety | SIL 2/3 certified to IEC 61508 |
| Warranty | Up to 15-year limited warranty |
| Country of Origin | USA |
| Measurement Type | Differential pressure, static pressure, process temperature |
Product Description
['Home', 'Flow Measurement', 'Rosemount', '3051SFA'] Need Emerson+Rosemount 3051SFA1G040CCHPS1T100T32JA1A3RLQ4M5? Annubar Flow Meter for Industrial flow measurement. Supplied with full traceability and... Price & Availability 2500.00 USD (参考价 / est. market price) Classified as an annubar flow meter, it is positioned as a direct replacement and service part for existing installations. It is intended for use within Industrial flow measurement, where dependable operation and a precise fit are essential to keeping the plant running. Listed as Active, it is offered as a maintained and verified spare that supports the continued operation of the installed base. Key technical specifications include: The Measurement Type is Differential pressure, static pressure, process temperature. Its Flow Accuracy is rated at Up to +/-0.80% of flow (Ultra for Flow: +/-0.04% of reading). For reference, the Stability is Up to +/-0.15% URL over 15 years. The Turndown is Up to 200:1 (14:1 flow turndown). Its Line Size is rated at 2 to 96 in (50 to 2440 mm). For reference, the Communication is 4-20 mA HART, WirelessHART, FOUNDATION Fieldbus. The Wetted Materials is 316 SST, Alloy C-276. Its Differential Pressure Range is rated at Up to 1000 inH2O (2.48 bar). For reference, the Pressure Range is Up to 3626 psia / 3626 psig (250 bar). The Safety is SIL 2/3 certified to IEC 61508. Its Warranty is rated at Up to 15-year limited warranty. For reference, the Country of Origin is USA. Notable features of this unit: Patented T-shaped Annubar sensor for low pressure loss. Built-in flow calculation for fully compensated mass flow. Up to 200:1 turndown (14:1 flow turndown). Multiple protocols: 4-20 mA HART, WirelessHART, FOUNDATION Fieldbus. Typical applications include Compensated mass and volumetric flow measurement, Steam, gas and liquid flow in process plants, Energy and custody-transfer flow metering. It is compatible with or cross-references Rosemount 3051S pressure platform, FOUNDATION Fieldbus host systems. The 3051SFA is configured via an option code covering sensor, flange, manifold and communication choices. The full option string defines the exact build; confirm with the supplier. Within industrial automation and process-control environments, components of this type are relied upon to keep critical equipment operating safely and efficiently. They are typically specified where uptime, repeatability and a predictable maintenance cycle matter more than upfront cost. A annubar flow meter such as this one forms part of a larger machine or system, so correct identification and fitment directly affect the performance and safety of the whole installation. Rosemount parts are widely used across power generation, manufacturing, oil and gas, water and process industries, where engineering teams standardise on proven series to simplify spares planning. When selecting a replacement, confirm the exact model designation and verify that the mechanical and electrical interface matches the unit currently installed. Cross-checking the order code, mounting style and connection type against the existing device helps avoid compatibility issues and unplanned downtime during a maintenance window. Where several variants exist, the suffix often defines voltage, range or firmware, so it should be matched precisely rather than approximated. This item is offered from our active stock of current and discontinued industrial parts. Each listing is verified against the manufacturer designation before shipment so you receive the correct part for your application. Availability and lead time vary by item; our team can confirm the fastest option for your required quantity and provide a formal quotation on request. Common questions: Regarding "What is the Rosemount 3051SFA": It is an Annubar flow meter on the 3051S platform that delivers fully compensated mass flow from one pipe penetration. Regarding "What communication protocols are supported": It supports 4-20 mA HART, WirelessHART and FOUNDATION Fieldbus. Please contact us to confirm current pricing, availability and delivery for your required quantity; volume and project pricing are available on request. The Rosemount 3051SFA1G040CCHPS1T100T32JA1A3RLQ4M5 is an annubar flow meter. Basic Product Information Built-in flow calculation for fully compensated mass flow Up to 200:1 turndown (14:1 flow turndown) Multiple protocols: 4-20 mA HART, WirelessHART, FOUNDATION Fieldbus Patented T-shaped Annubar sensor for low pressure loss Technical Specifications Version & Model Difference The 3051SFA is configured via an option code covering sensor, flange, manifold and communication choices. The full option string defines the exact build; confirm with the supplier. Application Scenarios Compensated mass and volumetric flow measurement Steam, gas and liquid flow in process plants Energy and custody-transfer flow metering What communication protocols are supported? It supports 4-20 mA HART, WirelessHART and FOUNDATION Fieldbus. What is the accuracy and turndown? Flow accuracy is up to +/-0.80% of flow (Ultra for Flow +/-0.04% of reading) with up to 200:1 turndown. How do I get pricing and delivery? Submit an inquiry to ZZSL with the full model string; we verify configuration, stock and provide a quote. What is the Rosemount 3051SFA? It is an Annubar flow meter on the 3051S platform that delivers fully compensated mass flow from one pipe penetration.
Need 3051SFA1G040CCHPS1T100T32JA1A3RLQ4M5?
Get a Quote in Minutes.
12-month warranty · No MOQ · Worldwide shipping with tracking
Request a Quote
Get the latest price, stock status and bulk order discount for 3051SFA1G040CCHPS1T100T32JA1A3RLQ4M5. Our team replies within 30 minutes (working hours).