Auto-extracted from partner page

Specifications

BrandAllen-Bradley
Model Number1756-EN2TR
Official Product NameControlLogix EtherNet/IP Bridge Module
Applicable SystemControlLogix
Product TypeCommunication Module
Equivalent StandardEtherNet/IP, IEEE 802.3
Product StatusIn Stock
Number of Ports2 (Copper RJ45)
Max TCP/IP Connections256
Max CIP Connections128
Processor1.6 GHz
Network TopologyStar, Device Level Ring (DLR)
Power Supply5.1V DC, 1.2A (from backplane)
Power Dissipation6.1 W
Thermal Dissipation20.8 BTU/hr
Operating Temperature0°C to 60°C (32°F to 140°F)
Non-Operating Temperature-40°C to 85°C (-40°F to 185°F)
Dimensions (H x W x D)14.2 x 8.7 x 5.3 cm (5.6 x 3.43 x 2.1 in)
Communication Rate10/100/1000 Mbps

Product Description

Home > Products > Allen-Bradley > ControlLogix > 1756-EN2TR Need Allen-Bradley 1756-EN2TR? Communication Module for ControlLogix. Supplied with full traceability and documentation. Request a quote and current... Price & Availability It provides dual Gigabit Ethernet ports with a data rate of 1 Gbps, enabling high-speed data exchange and integration into modern industrial networks. This module supports a wide range of applications, from machine-level control to plant-wide data collection, and is fully compliant with the EtherNet/IP standard, ensuring interoperability with other Rockwell Automation devices and third-party systems. Equipped with a powerful 1.6 GHz processor, the 1756-EN2TR delivers exceptional throughput and low latency, making it ideal for demanding applications such as motion control, high-speed discrete manufacturing, and process control. It supports up to 256 TCP/IP connections and 128 CIP connections, allowing seamless communication with numerous devices, including drives, I/O blocks, and HMIs. The module also features advanced network security options, including port filtering and protocol restrictions, to protect your control system from unauthorized access. The 1756-EN2TR is designed for easy integration into existing ControlLogix systems. It can be installed in any ControlLogix chassis and is compatible with RSLogix 5000 and Studio 5000 software versions 20 and later. The module supports both star and device-level ring (DLR) network topologies, providing flexibility in network design and redundancy. With its robust construction and reliable performance, the 1756-EN2TR is a trusted choice for industrial automation professionals seeking to enhance their network infrastructure. The Allen-Bradley 1756-EN2TR is a high-performance EtherNet/IP communication bridge module designed for the ControlLogix platform. Basic Product Information Supports up to 256 TCP/IP connections and 128 CIP connections High-speed 1.6 GHz processor for fast data exchange Supports Device Level Ring (DLR) for network redundancy Advanced network security with port filtering and protocol restrictions Compatible with RSLogix 5000 and Studio 5000 (v20 or later) Dual Gigabit Ethernet ports (10/100/1000 Mbps) with copper RJ45 connectors Technical Specifications Version & Model Difference The 1756-EN2TR is part of the ControlLogix EtherNet/IP bridge family. Compared to earlier models like the 1756-ENBT (10/100 Mbps) and 1756-EN2T (single port), the EN2TR offers dual Gigabit ports and a faster processor, enabling higher data throughput and support for more connections. It also adds DLR capability for resilient ring topologies. The 1756-EN2TR is the preferred choice for new installations requiring high performance and redundancy. Application Scenarios Can the 1756-EN2TR be used in a redundant system? Yes, the 1756-EN2TR supports DLR, which allows for network redundancy in ring topologies. For controller redundancy, you can use two EN2TR modules in a redundant chassis configuration. What software is required to configure the 1756-EN2TR? You need RSLogix 5000 or Studio 5000 Logix Designer version 20 or later. The module can be configured via the I/O tree in the software, and its IP address can be set using BOOTP/DHCP or the module's web interface. Is the 1756-EN2TR compatible with older ControlLogix processors like L61? Yes, the 1756-EN2TR is compatible with ControlLogix L6x and L7x processors, provided the firmware and software versions are updated to meet the module's requirements. Check the Rockwell Automation compatibility matrix for exact firmware versions. What is the difference between 1756-EN2T and 1756-EN2TR? The 1756-EN2T has a single Ethernet port, while the 1756-EN2TR has two ports. The EN2TR supports Device Level Ring (DLR) topology for redundancy, whereas the EN2T does not. Both support Gigabit speeds and have similar connection limits. Allen-Bradley 1734-IE8C POINT I/O 8-Channel Analog Input Allen-Bradley 800T-QH2R 30 mm Indicator Allen-Bradley 1746-P4 SLC 500 Power Supply Module Allen-Bradley 1756-L85E ControlLogix 5580 Controller Allen-Bradley 1756-L71 ControlLogix 5570 Controller Allen-Bradley 22B-D010N104 PowerFlex 40 AC Drive Allen-Bradley 1492-IFM40DS24A-4 Digital Interface Module Allen-Bradley 1492-IFM40F Digital Interface Module

READY TO SHIP · 48H

Need 1756-EN2TR?
Get a Quote in Minutes.

12-month warranty · No MOQ · Worldwide shipping with tracking

Request a Quote

Get the latest price, stock status and bulk order discount for 1756-EN2TR. Our team replies within 30 minutes (working hours).

Get Instant Quote