ABB Air Circuit Breaker E6H 50 5000 PR121/P-LSIG
E6H-50-5000-PR121P-LSIG

ABB
ABB Air Circuit Breaker E6H 50 5000 PR121/P-LSIG
Home > Products > ABB > Circuit Breaker ABB E6H 50 5000 PR121/P-LSIG Air Circuit Breaker. For Low-voltage power distribution. Supplied with full trace…
Contact us for current availability and best price of E6H-50-5000-PR121P-LSIG.
Specifications
| Brand | ABB |
|---|---|
| Model Number | E6H 50 5000 PR121/P-LSIG |
| Official Product Name | Emax2 E6H Air Circuit Breaker |
| Applicable System | Low-voltage power distribution |
| Product Type | Air Circuit Breaker |
| Equivalent Standard | N/A |
| Product Status | N/A |
| Rated current | 5000 A |
| Rated voltage | 690 V |
| Breaking capacity | 100 kA |
| Release | PR121/P with LSIG |
| Series | ABB Emax2 E6H |
Product Description
Confirm wiring, accessories and trip settings with your switchgear design before ordering. The ABB Emax2 E6H is a high-capacity air circuit breaker rated at 5000 A, 690 V with a 100 kA breaking capacity and the PR121/P protection release with LSIG functions.
Basic Product Information
- 5000 A rated current
- 690 V, 100 kA breaking capacity
- PR121/P release with LSIG protection
- Emax2 E6H air circuit breaker
Technical Specifications
Version & Model Difference
- Variant and suffix data for E6H 50 5000 PR121/P-LSIG is not published in public manufacturer documentation. Configurations are matched from the complete order code at quotation stage.
Application Scenarios
- Main incoming breakers
- Industrial power distribution
- Large motor protection
- ABB UNS 0017A-P Firing Board (SCR Trigger) for UNITROL 5000/6000 Excitation
- ABB KS D211B Input Coupling Unit (ICU) – UNITROL 6000
- ABB M35 UNS4017A-E Var. 633 Thyristor Packet (3BHE026955R0633)
- ABB SDCS-PIN-51-COAT Power Interface Board (3ADT220090R0006) – DCS800
- ABB PS 1500V 125A - 1500 V / 125 A Protection and Switching Device
- ABB FSCA-01 RS-485 Modbus-RTU Adapter Module
- ABB CCM 6080 / UC D240 A01 (3BHE022287R0001) Controller Board
- ABB CP-S.1 24/5.0 Switch Mode Power Supply 24V DC 5A 120W
Frequently Asked Questions
What current is the E6H rated for?
It is rated at 5000 A with a 690 V rating and 100 kA breaking capacity.
What does PR121/P-LSIG mean?
PR121/P is the protection release; LSIG denotes Long-time, Short-time, Instantaneous and Ground-fault protection functions.
Which series is this?
It belongs to the ABB Emax2 family of air circuit breakers.
Can I get a cross-reference?
The verified parameters for E6H 50 5000 PR121/P-LSIG are: Series: ABB Emax2 E6H; Rated current: 5000 A; Rated voltage: 690 V; Breaking capacity: 100 kA; Release: PR121/P with LSIG.
Need E6H-50-5000-PR121P-LSIG?
Get a Quote in Minutes.
12-month warranty · No MOQ · Worldwide shipping with tracking
Request a Quote
Get the latest price, stock status and bulk order discount for E6H-50-5000-PR121P-LSIG. Our team replies within 30 minutes (working hours).